1000W to 1500W Single Output General Purpose Power SuppliesFeaturesCost Effective Wide Range AC Input 85 - 265VAC Enclosed Construction Compact Sizes SEMI F47 Line Dips 7 Year WarrantySpecificationsMo
1000W to 1500W Single Output General Purpose Power SuppliesFeaturesCost Effective Wide Range AC Input 85 - 265VAC Enclosed Construction Compact Sizes SEMI F47 Line Dips 7 Year WarrantySpecificationsMo
Cost Effective
Wide Range AC Input 85 - 265VAC
Enclosed Construction
Compact Sizes
SEMI F47 Line Dips
7 Year Warranty
Specifications | |||
Model RWS1000B RWS1500B | |||
AC Input Voltage range (1) | VAC | 85 - 265VAC (47 - 63Hz) | |
DC Input Voltage range* | VDC | 120 - 340VDC* | |
Inrush Current (100 / 200VAC) | A | 60 / 60A | |
Power Factor (100 / 200VAC) | - | Meets EN61000-3-2 (0.98 / 0.95) | |
Input Current (100/200VAC) (Typ) | A | 13 / 7A | 19 / 10A |
Temperature Coefficient | %/°C | <0.02%/°C | |
Regulation | - | See Model Selector | |
Overcurrent Protection | - | >105%, Constant Current Style. After 5s unit will shutdown | |
Overvoltage Protection | V | 120-145% (115-125% for 48V), Cycle AC line to reset | |
Hold Up Time (Typ at 100% load) | ms | 20ms | |
Leakage Current (max) | mA | <1.2mA | |
Remote Sense | - | Yes | |
Remote On/Off | - | See options table. Apply external voltage to enable output voltage | |
DC Good, Fan Alarm | - | See options table | |
Parallel Operation | - | See options table | |
Series Operation | - | Yes | |
Operating Temperature | °C | -20 to +60°C, derate linearly to 60% load from 50 to 60°C | |
Storage Temperature | °C | -30 to +75°C | |
Operating Humidity (non condensing) | %RH | 20 - 90%RH | |
Storage Humidity (non condensing) | %RH | 10 - 90%RH | |
Cooling | - | Internal Fan, air intake from input/output terminals | |
Withstand Voltage | VAC | Input to Ground 2kVAC, Input to Output 4kVAC, Output to Ground 1.5kVAC for 1 min. | |
Isolation Resistance | MΩ | >100MΩ at 25°C & 70%RH, Output to Ground 500VDC | |
Vibration (non operating) | 10 - 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour | ||
Shock | - | < 196.1 m/s2 | |
Safety Agency Certifications | - | UL60950-1, CSA60950, EN60950-1, CE Mark | |
Line Dips | - | SEMI-F47 (200VAC input) | |
Conducted & Radiated EMI | - | EN55011 / EN55032-B, FCC Class B, VCCI-B | |
Immunity | - | IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2 | |
Weight (Typ) | g | 2,000g | 3,000g |
Size (WxHxD) | mm In | 127 x 63 x 198mm 5 x 2.48 x 7.8” | 127 x 63 x 261mm 5 x 2.48 x 10.28” |
MTBF - Telcordia SR-332 issue 3** | hours | 1,834,313 | 1,222,361 |
Warranty | yrs | Seven Years |