Specifications

Model RWS50B RWS100B RWS150B RWS300B RWS600B

AC Input Voltage range (1)

VAC

85 - 265VAC (47 - 63Hz), 300VAC for 5 seconds

DC Input Voltage range

VDC

120 - 370VDC (330VDC for RWS600B)*

Inrush Current (100 / 200VAC)

A

18 / 36

15 / 30

16 / 32

17 / 34

20 / 40

Power Factor (100 / 200VAC)

-

Meets EN61000-3-2 (0.95 / 0.9)

Input Current (115/230VAC) (Typ)

A

1.0 / 0.65

1.2 / 0.6

(5V: 0.9/0.45)

1.8 / 0.9

(5V: 1.3/0.7)

3.6 / 1.9

(5V: 3.1/1.6)

6.6 / 3.6

(5V: 6.2/3.2)

Temperature Coefficient

-

<0.02%/°C

Regulation

-

See sheet 2

Overcurrent Protection

-

>105%, Constant Current Style

Overvoltage Protection

V

115-140%, Cycle AC line to reset

Hold Up Time (Typ at 100% load)

ms

20ms (RWS50B: 15ms at 100VAC input)

Leakage Current (max)

uA

750uA maximum, typically 175uA at 115VAC, 63Hz

Remote Sense

-

No

Operating Temperature

-

-20 to +70oC, see note (3) and instruction manual for low temperature derating

Storage Temperature

-

-30 to +75°C

Operating Humidity (non condensing)

%RH

30 - 90%RH

Storage Humidity (non condensing)

%RH

10 - 90%RH

Cooling

-

Convection

Internal Fan

Withstand Voltage

-

Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.

Isolation Resistance

-

>100M at 25°C & 70%RH, Output to Ground 500VDC

Vibration (non operating)

-

10 - 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour

Shock

-

< 196.1 m/s2

Safety Agency Approvals (2)

-

UL / CSA(cUL) / IEC 60950-1 (2nd Ed), UL:508, CSA C22.2 No.107.1-01,

CE Mark (Additionally evaluated to EN 60950-1)

Conducted & Radiated EMI

-

EN55011 / EN55022-B, FCC Class B, VCCI-B

Immunity

-

IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2

Weight (Typ)

g

230

400

480

900

1600

Size (WxHxD)

mm

82 x 34 x 81.5

94 x 39 x 108

94 x 41 x 128

102 x 41 x 170

120 x 61 x 190


In

3.23 x 1.34 x 3.2

3.7 x 1.54 x 4.25

3.7 x 1.61 x 5.04

4.02 x 1.61 x 6.7

4.72 x 2.4 x 7.48

MTBF - Telcordia SR-332 issue 3**

Hours

4,170,949

1,978,533

2,235,743

2,027,824

2,157,340

Warranty

Yrs

Seven Years